Mode
l : MLC-03 Control Unit MLS-03
Sensors (S1,S2,S3)
Supply Voltage :
24 V DC
Sensing Distance (Straight
Line) : 125mm to 250mm
Advantages
: Automatic control of feed
motor to regulate the cotton flow is achieved. The
unit controls the feeding system to attain uniform, continuous
output. Choking of cotton fibers is completely
avoided.
Application
: It is an Electronic Photo
Cell unit consists of one control unit and three sensor
assemblies. The two sensors are mounted at the Top level and
third at the Bottom level of the transparent chute
face (Glass Panel) to maintain the cotton level. The TOP sensors
(S1/S2) switches off the feed motor when blocked by cotton
within a preset time. The BOTTOM sensor (S3) switches
the motor from high speed to slow speed when blocked
by cotton within a preset time. |